Manufacturer: Keysight / Agilent / HP
Model: DSOX4052A

Keysight / Agilent DSOX4052A Oscilloscope, 500 MHz, 2 Chs.

Electronic Test and Measurement Equipment

Keysight / Agilent DSOX4052A Oscilloscope, 500 MHz, 2 Chs. Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT KEYSIGHT  DSOX4052A (AGILENT) OSCILLOSCOPE (Call for Availability)

The Keysight  DSOX4052A (Agilent) is a two-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The DSOX4052A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.

Features and Specifications of the Keysight  DSOX4052A Agilent) Oscilloscope include:

Features of the Agilent DSOX4052A include:

  • One million waveforms per second update rate
  • MegaZoom IV smart memory technology
  • Standard segmented memory
  • Large 12.1-inch capacitive touch display
  • Interface designed for touch
  • Innovative InfiniiScan Zone touch triggering
  • 5 instruments in 1, with full upgradability, including bandwidth:
    • Oscilloscope  
    • Logic analyzer (MSO) 
    • Serial protocol analyzer, including USB (optional)
    • WaveGen 20 MHz dual channel arbitrary/function generator (optional)
    • Digital voltmeter (DVM) option:
      • with 3-digit voltage
      • with 5-digit frequency counter measurements

Specifications of the Keysight  DSOX4052A include:

  • Bandwidth (-3 dB):  500 MHz
  • All-channel real-time bandwidth:  500 MHz
  • Calculated rise time (10 - 90%):  ≤ 700 ps
  • Input channels:  2 analog
  • Maximum sample rate:
    • 5 GSa/s half channel
    • 2.5 GSa/s all channel
  • Maximum memory depth:  Standard 4 Mpts, standard segmented memory
  • Display size and type:  12.1-inch high-definition capacitive touch display
  • Waveform update rate:  > 1 million waveforms per second
  • System bandwidth with N2894A standard passive probe: 500 MHz
  • Vertical system analog channels:
    • Hardware bandwidth limits:  Approximately 20 MHz (selectable)
    • Input coupling:  AC, DC
    • Input impedance:  Selectable:  
      • 1 MΩ ± 1% (16 pF)
      • 50 Ω ± 1.5%
    • Input sensitivity range:  1mV/div to 5 V/div (1 MΩ and 50 Ω)
    • Vertical resolution:  8 bits (measurement resolution is 12 bits with averaging)
    • Maximum input voltage:
      • 300 Vrms, 400 Vpk
      • Transient overvoltage 1.6 kVpk
      • With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
      • Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
    • DC vertical gain accuracy: ± 2.0% full scale
    • DC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting
    • Channel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model
    • Offset range:
      • ± 5 V (< 10 mV/div)
      • ± 20 V (10 to 200 mV/div)
      • ± 75 V (> 200 mV/div)
  • Vertical system digital channels:
    • Digital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
    • Thresholds: Threshold per pod
    • Threshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
    • User-defined threshold range:  ± 8.0 V in 10 mV steps
    • Maximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk
    • Threshold accuracy:  ± (100 mV + 3% of threshold setting)
    • Maximum input dynamic range:  ± 10 V about threshold
    • Minimum voltage swing:  500 mVpp
    • Input impedance:  100 kΩ ± 2% at probe tip
    • Input capacitance:  ~8 pF
    • Vertical resolution: 1 bit
  • Horizontal system analog channels:  
    • Time base range:  2 ns/div to 50 s/div
    • Time base accuracy:  ± 10 ppm
    • Time base delay time range:
      • Pre-trigger:  Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
      • Post-trigger: 1 s to 500 s
    • Channel-to-channel deskew range:  ± 100 ns
    • Δ Time accuracy (using cursors):  ± 0.001% of reading ± 0.16% screen width ± 30pS
    • Modes:  Main, zoom, roll, XY
    • XY:
      • On channels 1 and 2 only
      • Z Blanking on ext trigger input, 1.4 V threshold  
      • Bandwidth:  Maximum bandwidth
      • Phase error at 1 MHz: < 0.5 degree
      • Time base: 200 ns/div to 50 ms/div
  • Horizontal system digital channels:  
    • Minimum detectable pulse width:  2 ns
    • Channel-to-channel skew:
      • 2 ns (typical)
      • 3 ns (maximum)
  • Aquisition system:
    • Maximum analog channels sample rate:  
      • 5 GSa/s half channel interleaved
      • 2.5 GSa/s all channel
    • Maximum analog channels record length:
      • 4 Mpts half channel interleaved
      • 2 Mpts all channel
    • Modes:
      • Normal:  Default mode
      • Peak detect:  Capture glitches as narrow as 200 ps at all time base settings
      • Averaging:  Selectable from 2, 4, 8, 16, 64, ... to 65,536
      • High resolution:
        • Real time boxcar averaging reduces random noise and effectively increases vertical resolution
        • 12 bits:  ≥ 50 μs/div
        • 11 bits:  ≥ 20 μs/div
        • 10 bits:  ≥ 10 μs/div
        • 9 bits:  ≥ 5 μs/div
      • Segmented:
        • Segmented memory optimizes available memory for data streams that have long dead times between activity
        • Maximum segments = 1000
        • Re-arm time = 1 μs (minimum time between trigger events)
        • Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)
      • Roll:  
        • Displays the waveform moving across the screen from right to left
        • Available at the time base 50 ms/div or slower
  • Trigger system:
    • Trigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
    • Trigger modes:
      • Normal: Requires trigger event for scope to trigger
      • Auto : Triggers automatically in absence of trigger event
      • Single:
        • Front panel button that triggers only once on a trigger event
        • Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode
      • Force:  Front panel button that forces a trigger
    • Trigger coupling:  
      • DC: DC coupled trigger
      • AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)
      • High frequency reject:  Cutoff frequency ~ 50 kHz
      • Low frequency reject:  Cutoff frequency ~ 50 kHz 
      • Noise reject:
        • Adds hysteresis to the trigger circuitry
        • Selectable OFF or ON
        • Decreases sensitivity 2x
    • Trigger holdoff range: 40 ns to 10.00 s  
    • Trigger sensitivity:
      • Internal:
        • < 10 mV/div: greater of 1 div or 5 mV
        • ≥ 10 mV/div: 0.6 div
      • External:
        • ± 1.6 V:  
          • 40 mVpp DC to 100 MHz
          • 70 mVpp 100 MHz to 200 MHz
        • ± 8 V:  
          • 200 mVpp DC to 100 MHz
          • 350 mVpp 100 MHz to 200 MHz
    • Trigger level range:
      • Any channel:  ± 6 div from center screen
      • External:  
        • ± 8 V range = ± 8 V
        • ± 1.6 V range = ± 1.6 V
  • Connectivity:
    • USB 2.0 hi-speed host port:
      • x3 ports, 2 front and one rear panel
      • Supports memory devices, printers, keybords and mice
    • USB 2.0 hi-speed device port:
      • One port on rear panel
      • USB Test & Measurement Class (USBTMC) compatible
    • LAN port:
      • 10/100Base-T port on rear panel
      • LXI IPv6 extended function
    • Web remote control:  VNC Web interface (via major Web browsers)
    • Video out port:  
      • SVGA out on rear panel
      • Connect oscilloscope display to an external monitor or projector
    • GPIB port:  N4865A GPIB-to-LAN adapter (optional)
    • 10 MHz out/in:  
      • BNC connector on the rear panel
      • Suported modes:  Off, 10 MHz out, or reference signal mode (10 MHz in)
    • Trigger out:  
      • BNC connecter on the rear panel 
      • Supported modes:  triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

Working with Axiom has always been fruitful and painless.  So thank you.  You’re always my first call when I need something.  


-- Ed C
Fremont, CA



Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

Thank you for your quick response to our need.

Brenda S.
Loveland, CO




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600