EMTEST UCS200N / EM Test UCS 200N

The EM Test UCS 200N Ultra-Compact Simulator for Automotive Transients unifies the capabilites of an EFT/Burst simualtor, a Micropulse simulator and the required coupling network into one box. The UCS 200N Transient Tester is equiped to meet all international and car manufacturer specifications from around the globe. The built-in coupling network ranges from 50A, up to 200A depending on the model / option specified. The built-in coupling network can be used and controlled by any unit of the LD 200N, VDS 200N and PFS 200N. For tests beyond standard's requirements the waveform parameters of the Micropulse generator can be varied in a wide range by means of the FreeStyle mode.

The EM Test UCS200N has the following specifications:

UCS 200N MODELS

  • UCS 200N50 Built-in coupling/decoupling network, 80V/50A, 100A@500ms
  • UCS 200N100 Built-in coupling/decoupling network, 80V/100A, 150A@500ms
  • UCS 200N150 Built-in coupling/decoupling network, 80V/150A
  • UCS 200N200 Built-in coupling/decoupling network, 80V/200A

INPUT:

  • DUT supply +/-: DC voltage from VDS 200N or any other DC supply
  • Pulse 5, 7: From one LD 200N

OUTPUT:

  • DUT supply +/-: Central DUT output
  • Coaxial output port: To connect the capacitive coupling clamp as per ISO 7637-3:2007

ELECTRICAL FAST TRANSIENTS

 

EFT/BURST MODULE FOR TEST PULSES 3A/3B As per ISO 7637-2

  • Test voltage: 25V - 1,000V ± 10%
  • Rise time: 5ns ± 1.5ns
  • Pulse duration: 150ns ± 45ns
  • Verification: As per Annex C of ISO 7637-2:2011 into 50ohm and 1,000ohm load
  • Source impedance: Zq = 50ohm
  • Polarity: Positive/negative (Pulse 3b/3a)

TRIGGER CIRCUIT

  • Trigger of bursts Automatic: manual, external
  • Burst duration: T4 = 0.1ms - 999.9ms
  • Repetition rate: T5 = 10ms - 9,999ms
  • Spike frequency: f = 0.1kHz - 200kHz
  • Test duration: T = 0:01min - 999:59min, T > 999:59min --> endless

OUTPUTS

  • Direct: Via 50ohm-coaxial connector (for tests using e.g. a capacitive
  • coupling clamp)
  • Coupling mode: To the + battery line (supply lines)
  • CRO trigger: 5V trigger signal for oscilloscope

TEST ROUTINES

  • Quick Start: On-line adjustable parameters, easy-to-use
  • Standard Test Routines: As per ISO 7637-2:2011, Levels 1 - 4
  • User Test Routines: Random burst release. Change voltage after T. Change frequency after T

MICROPULSES

 

MICROPULSE MODULE FOR TEST PULSES 1, 2A AND 6: As per ISO 7637-2:2011

  • Test voltage:  U = 20V - 600V ± 10% (peak voltage and polarity as per selected standard)
  • Repetition rate: 0.2s - 99.0s

ISO PULSE 1 (12V)

  • Rise time: 1us +0%/-50% (10% - 90%)
  • Pulse duration: 2ms ± 10% (10% - 10%)
  • Int. resistor: 10ohm ± 10%

ISO PULSE 1 (24V)

  • Rise time: 3us +0%/-50% (10% - 90%)
  • Pulse duration: 1ms ± 10 (10% - 10%)
  • Int. resistor: 50ohm ± 10% 

ISO PULSE 2 (12V/24V)

  • Rise time: 1us +0%/-50% (10% - 90%)
  • Pulse duration: 50us ± 10% (10% - 10%)
  • Int. resistor: 2ohm ± 10%

ISO PULSE 6 (12V) AS PER ISO 7637-1:1990

  • Rise time: 60us +0%/-50% (10% - 90%)
  • Pulse duration: 300us ± 10% (10% - 10%)
  • Int. resistor: 30ohm ± 10% 

AS PER ISO 7637-2 THE FOLLOWING STANDARDS CAN BE COVERED

  • SAE J1113
  • GM 3097
  • BMW
  • Volkswagen
  • PSA
  • Chrysler PF 9326
  • DC 10614
  • Renault
  • FIAT
  • Mitsubishi
  • Honda
  • Ford ES-XW7T

TRIGGER

  • Automatic: Automatic release of the pulses
  • Manual: Manual release of a single pulse
  • External: External release of a single pulse
  • Battery switch: Off time, selectable; 0 - 10,000ms

OUTPUT

  • DUT supply +/-: Central DUT output
  • Coupling: To the battery +line
  • Decoupling: Via diode and battery supply switch

TEST ROUTINES

  • Quick Start: Immediate start; easy to use and fast
  • User Test Routines: 1. Custom made test routines and 2. Change voltage after n pulses
  • Standard Test Routines: As per ISO 7637, SAE J1113, JASO and manufacturer specifications
  • Service: Service, setup, self test

Request A Quote

Rent      Buy      Repair
SUBMIT REQUEST
760-806-6600


Testimonial







Home   |   Rental Equipment   |   Equipment Sales   |   Repair & Calibration   |   Sell Your Equipment   |   About Us   |   Contact   |   Get A Quote   |   Blog    



YouTube Facebook Google Plus Paypal
Get the latest deals first. Subscribe to our newsletter.    SUBSCRIBE


© 2020 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML     
© 2020 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
Phone: (760) 806-6600