Manufacturer: Keysight / Agilent / HP
Model: E4361A

Keysight / Agilent E4361A Solar Array Simulator DC Module, 65V, 8.5A, 510W

Electronic Test and Measurement Equipment

Keysight / Agilent E4361A Solar Array Simulator DC Module, 65V, 8.5A, 510W  Product Datasheet Download Product Datasheet

Rent Test Equipment

Available Option Configurations

Config-01

  • No Options Included
  • MSRP: $8,354 | Available for Rental    GET QUOTE  

Product Overview

RENT AGILENT / HP E4361A Solar Array Simulator DC Module (call for availability)

The Agilent / HP E4361A is a 510W Solar Array Simulator DC Power Module that simulates the output characteristics of a solar array. The Agilent / HP E4361A Solar Array Simulator DC Module is primarily a current source with very low output capacitance. It offers fast I-V curve changes allowing you to accurately simulate the output of different solar arrays under various environmental conditions (ie., temperature, age, eclipse, spin etc.). The Agilent / HP E4361A Solar Array Simulator DC Module gives you the flexibility to operate it in two ways:

  • Input the four key operational parameters (Voc, Isc, Vmp, Imp) needed for the Solar Array Simulator to internally create an I-V curve of a solar array
  • Download a user defined table for the I-V curve of the solar array

Features and Specifications of the Agilent / HP E4361A Modular Solar Array Simulator DC Module include:

  • Output Ratings (Simulator and Table Modes):
      • Maximum Power:  510 W
      • Maximum Open Circuit Voltage (Voc):  65 V
      • Maximum Voltage Point (Vmp):  60 V
    • Line Voltage 200 V / 230 V / 240 V:
      • Maximum Short Circuit Current (Isc):  8.5 A
      • Maximum Circuit Point (Imp):  8.5 A
    • Line Voltage: 100 V / 120 V:
      • Maximum Short Circuit Current (Isc):  4.25 A
      • Maximum Circuit Point (Imp):  4.25 A
  • Output Ratings (Fixed Mode):
    • Voltage:  0 - 60 V
    • Line Voltage: 200 V / 230 V / 240 V
      • Current:  0 - 8.5 A
    • Line Voltage:  100 V / 120 V
      • Current:  0 - 4.25 A
  • Current Derating Factor (from 40°C to 55°C):  0.11 A/°C
  • Output Voltage Ripple & Noise (from 20 Hz to 20 MHz with a resistive load, outputs ungrounded, or either output grounded):
      • Simulator / Table Mode:
        • 20 mVrms
        • 125 mVp-p
      • Fixed Mode (constant voltage):
        • 24 mVrms
        • 150 mVp-p
  • Programming Accuracy (@ 23°C ±5°C):
      • Fixed Mode Voltage:  0.075% + 25 mV
      • Fixed Mode Current:  0.2% + 20 mA
  • Readback Accuracy (from front panel or over GPIB with respect to actual output @ 23 ±5°C):
      • Voltage:  0.08% + 25 mV
      • +Current:  0.20% + 20 mA
      • -Current:  0.35% + 48 mA
  • Load Regulation - Fixed Mode (change in output voltage or current for any load voltage change within ratings):
      • Constant Voltage:  2 mV
      • Constant Current:  1 mA
  • Line Regulation - Fixed Mode (change in output voltage or current for any line voltage change within ratings):
      • Constant Voltage:  2 mV
      • Constant Current:  1 mA
  • Output Current Ripple & Noise (from 20 Hz to 20 MHz with a resistive load, outputs ungrounded, or either output grounded):
      • Simulator/Table Mode:
        • 4 mArms
        • 32 mAp-p
      • Fixed Mode (constant current):
        • 2.5 mArms
        • 19 mAp-p
  • Output Programming Range (maximum programmable values):
      • Simulator/Table Mode Voltage:  0 - 65 V
      • Fixed mode Voltage:  0 - 61.5 V
    • Line Voltage:  200 V / 230 V / 240 V:
      • Current:  0 - 8.66 A
    • Line Voltage: 100 V / 120 V:
      • Current:  0 - 4.33 A
      • Overvoltage Protection:  0 - 74 V
      • Overcurrent Limit:  0 - 10.6 A
  • Programming Resolution (average values):
      • Voltage:  19 mV
      • Current:  2.7 mA
      • Overvoltage Protection:  325 mV
      • Overcurrent Limit:  46 mA
  • Programming Accuracy:
      • Overvoltage Protection:  0.65 V
      • Overcurrent Limit:  0.5% + 215 mA
      • Current Monitor (referenced to P common):  1.0% + 130 mA
  • Fixed Mode Analog Current Programming:
      • Analog Programming:  1.0% + 5.5 mA
      • +Ip to -Ip Differential Input (0 to full scale):  0 to -4 V
      • Maximum Common Mode Voltage (referenced to +OUT): ±18 V
      • Nominal Input Impedance:  20 kO
  • Drift / Temperature Stability (change in output over 8 hours underconstant load, line, and ambient, following a 30 minute warmup):
      • Voltage:  0.04% + 1 mV
      • Current:  0.1% + 0.85 mA
  • Temperature Coefficients (output change per °C):
      • Voltage:  0.01% + 325 µV
      • Current:  0.025% + 215 µA
  • Output Capacitance:  < 100 nF
  • Maximum Reverse Diode Current (with fans running):  8.5 A
  • Output Current Settling Time (output recovery to within 1.5 A of an operating point on the I-V curve (V < 90% of VMP) after switching from a short circuit to a fixed load):  < 5 µs
  • Maximum Capacitive Load (for stable operation):
      • Simulator/Table Mode:  No Restriction
      • Fixed Mode:  2000 µF
  • Load Lead Drop with Remote Sensing:
      • Simulator/Table Mode:  Up to 2 volts + (Voc - Vmp)
      • Fixed Mode:  Up to 2 volts total
  • Current Sinking Capability:
      • Simulator/Table Mode:  350 mA
      • Fixed Mode:  420 mA
  • Voltage Programming Rise/Fall Time (time for output to change from 90% to 10% or 10% to 90% of its total excursion):  < 8 ms
  • Voltage Programming Settling Time (time for output change to settle within 0.1% of the rating of the unit; either 60 mV or 120 mV):  25 ms typical
  • Monotonicity:  Output is monotonic over entire rated voltage, current, temperature range
  • Auto-Parallel Configuration:  Up to 4 outputs
  • Series and Shunt Switching Frequency (switching frequency is controlling by a customer-supplied external series or shunt FET connected to the output):  50 kHz maximum
  • Output Terminal Isolation (maximum, from chassis ground):  ±240 Vdc

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

Great RF Test Equipment, in very good condition. I am very satisfied with the purchase and also with your management. It has been a pleasure to do business with you, and I hope to go on.


-- Jose




Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

Axiom has been a huge help to our success in the high demand of Silicon Valley. We are pleased to continue to work with Axiom for our equipment needs.

Tony W.
Newark, CA




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600