Magna-Power TSD600-72 Power Supply, 600V, 72A, 45kW Rental, Repair, Rent, Used


Tektronix Encore




Magna-Power TSD600-72
Power Supply, 600V, 72A, 45kW

Power Supplies >> >> Power Supply, 600V, 72A, 45kW
Rent Used Test Equipment
Manufacturer: Magna-Power
Model: TSD600-72

Magna-Power TSD600-72 Power Supply, 600V, 72A, 45kW

Electronic Test and Measurement Equipment

Magna-Power TSD600-72 Power Supply, 600V, 72A, 45kW Product Datasheet Download Product Datasheet

Rent Test Equipment

Available Option Configurations

Config-01

  • GPIB - GPIB Interface
  • TSD - Extended Control Front Panel
  • MSRP: $29,830 | In Stock!    GET QUOTE  

Config-02

  • TSD - Extended Control Front Panel
  • MSRP: $29,235 | In Stock!    GET QUOTE  

Product Overview

RENT MAGNA-POWER TSD600-72

The Magna-Power Electronics TSD600-72 combines the best of DC power processing with microprocessor embedded control. Magna-Power Electronics' innovative power processing technology improves response, shrinks package size, and reduces cost. The Magna-Power TS Series power supplies are current-fed and are more tolerant to abusive loads than conventional switching power supplies. This technology allows the power supply to operate under short-circuit conditions, open-circuit conditions, and everything in between.

TS Series power supplies offer both master/slave parallel and series operation. This enables two or more power supplies to be placed in parallel for increased output current or in series for increased output voltage. With master/slave operation, power supplies operate at near equal voltage and current.

TS Series power supplies can operate as a voltage source or current source depending on the control settings and load conditions. If the power supply is operating as a voltage source and the load increases to a point beyond the current command setting, the power supply automatically crosses over to current mode control and operates as a current source at that setting.

Specifications of the Magna-Power TSD600-72 High Voltage Power Supply include: 

Input:

  • AC Input Nominal Voltage: 
    • 208 Vac, 3Φ (operating range 187 - 229 Vac)
    • 240 Vac, 3Φ (operating range 216 - 264 Vac)
    • 380 Vac, 3Φ (operating range 342 - 440 Vac)
    • 415 Vac, 3Φ (operating range 373 - 456 Vac)
    • 440 Vac, 3Φ (operating range 396 - 484 Vac)
    • 480 Vac, 3Φ (operating range 432 - 528 Vac)
  • Frequency: 50 Hz - 400 Hz (operating range 45 - 440 Hz)
  • Power Factor: > 92% at maximum power

Output:

  • Ripple: 250 mVrms
  • Line Regulation:
    • Voltage Mode: ± 0.004% of full scale
    • Current Mode: ± 0.02% of full scale
  • Load Regulation
    • Voltage Mode: ± 0.01% of full scale
    • Current Mode: ± 0.04% of full scale
  • Load Transient Response: 2 ms to recover within ±1% of full scale output, with a 50% to 100% or 100% to 50% step load change
  • Efficiency: 88% at full load
  • Stability: ± 0.10% for 8 hrs. after 30 min. warmup
  • Isolation:
    • User inputs and outputs: referenced to earth ground
    • Maximum input voltage to ground: ±2500 Vac
    • Maximum output voltage to ground: ±1000 Vdc
  • Maximum Slew Rate: 100 ms for output voltage change from 0 to 63% 100 ms for output current change from 0 to 63%
    • With High Slew Rate Option (+HS): 4 ms for output voltage change from 0 to 63% 8 ms for output current change from 0 to 63%
  • Bandwidth: 3 Hz for remote analog voltage programming 2 Hz for remote analog current programming
    • With High Slew Rate Option (+HS): 60 Hz for remote analog voltage programming 45 Hz for remote analog current programming
  • Dimensions: 62.5 x 48 x 31.5 in (158.8 x 121.9 x 80.0 cm)
  • Weight: 349 lbs (158.3 kg

Control:

  • Voltage Programming Accuracy: ± 0.075% of full scale voltage
  • OVT Programming Accuracy: ± 0.075% of full scale voltage
  • Current Programming Accuracy: ± 0.075% of full scale current
  • OCT Programming Accuracy: ± 0.075% of full scale current
  • Voltage Readback Accuracy: ± 0.2% of full scale voltage
  • Current Readback Accuracy: ± 0.2% of full scale current External
  • Analog Programming and Monitoring Levels: 0 - 10 Vdc
  • External Analog Output Impedances
    • Voltage output monitoring: 100 Ω
    • Current output monitoring: 100 Ω
    • +10 Vdc reference: 1 Ω
  • External Digital Programming and Monitoring Limits:
    • Input: 0 to 5 Vdc, 10k input inpedance
    • Output: 0 to 5 Vdc, 5 mA drive capacity
  • Remote Sense Limits: 3% maximum voltage drop from output to load
  • Period Programming Limits: Minimum period: 10 ms Maximum period: 9997 sec


Request A Quote

Rent      Buy      Repair
SUBMIT REQUEST
760-806-6600


Testimonial







Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Sell Your Equipment   |   About Us   |   Contact   |   Get A Quote   |   Blog    


Facebook Google Plus Paypal
Get the latest deals first. Subscribe to our newsletter.    SUBSCRIBE


© 2017 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML     
© 2017 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
Phone: (760) 806-6600