Tektronix Encore

Transcat




Sorensen SGA60-333
DC Power Supply, 60V, 333A, 20kW

Power Supplies >> DC Power Supplies, High Voltage (60V and up), High Current (60A and up) >> DC Power Supply, 60V, 333A, 20kW
Rent Used Test Equipment
Manufacturer: Sorensen
Model: SGA60-333

Sorensen SGA60-333 DC Power Supply, 60V, 333A, 20kW

Electronic Test and Measurement Equipment

Sorensen SGA60-333 DC Power Supply, 60V, 333A, 20kW Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT SORENSEN SGA60-333 DC POWER SUPPLY (Call for Availability)

The Sorensen SGA60-333 DC Power Supply (SGA = Sorensen General Purpose Analog), is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the high power density. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units. The Sorensen SGA60-333 with its high performance power electronics, meets the need for simple front panel analog controls or external control.

Features and Specifications of the Sorensen  SGA60-333 DC Power Supply include:

Features:

  • 10-turn potentiometers for setting voltage and current
  • 3 ½ digit LED readout
  • Front panel over-voltage protection (OVP) preview/adjustment and reset
  • High power density up to 20 kW in a 3U chassis
  • Wide voltage range: up to 60V
  • Fast load transient response means protection from undesired voltage excursions
  • Low ripple and noise
  • Hardware trigger (Ethernet option)
  • Parallelable up to 150 kW make it expandable as requirements grow
  • Sequencing: free system controller and speed up test
  • Low audible noise with temperature controlled variable speed fans

Specifications:

  • Common:
    • Remote Sense:
      • Terminals are provided to sense output voltage at point of load
      • Maximum line drop 5% of rated voltage per line for 40-100V models
      • Greater line drop is allowed, but output regulation specifications no longer apply
    • Parallel Operation:
      • Up to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy
      • Additional paralleled SG units will add 0.3% inaccuracy per unit
    • Series Operation:  Up to 2 units
  • Input:
    • Nominal Voltage 3 phase, 3 wire + ground:
      • 208/220 VAC (operating range 187 - 242 VAC)
      • 380/400 VAC (operating range 342 - 440 VAC)
      • 440/480 VAC (operating range 396 - 528 VAC)
    • Frequency:  47 - 63Hz, 400Hz
    • Power factor:
      • >0.9 typical for 10V - 30V, 50V, 1000V and other models with optional "PF" modification
      • >0.75 typical for 208/220 VAC input (40V, 60V - 800V models, 0.9 available with modification "PF")
      • >0.72 typical for 380/480 VAC input (40V, 60V - 800V models, 0.9 available with modification "PF")
      • >0.69 typical for 440/480 VAC input (40V, 60V - 800V models, 0.9 available with modification "PF")
    • Protection:
      • ½ cycle ride through, typical, on all three phases
      • 3 cycle ride through on single phase
      • Missing phase shutdown (800V model 6.4 msec on all 3 phases)
  • Programming & Read-back Specifications:
    • Front Panel Display: 
      • Programming:
        • Accuracy: +/- (0.5%fs + 1 digit)
        • Resolution: 3.5 digits
      • Read-Back Monitoring:
        • Accuracy: +/- (0.5%fs + 1 digit)
        • Resolution: 3.5 digits
      • Knob control & Display read-back
    • Remote Analog Interface: 
      • Programming:
        • Accuracy:
          • Voltage: +/-0.25% of full scale 
          • Current: 0.8% of full scale 
      • Read-Back Monitoring:
        • Accuracy: +/-1.0% of full scale
      • 25-pin D-sub connector (0~5 V or 0~10 V)
    • Remote Digital Interface:
      • Programming:
        • Accuracy:
          • Voltage:  +/- 0.1% of full scale
          • Current: +/- 0.4% of full scale
        • Resolution: +/-0.002% of full scale
      • Read-Back Monitoring:
        • Accuracy:
          • Voltage:  +/- 0.1% of full scale
          • Current:  +/- 0.4% of full scale
        • Resolution:  +/-0.002% of full scale
    • OVP:
      • Programming:
        • Accuracy: +/- 1% of full scale
        • Resolution: +/-0.002% of full scale
      • Programming range:
        • 5-110%
        • Configured from front panel
        • Remote analog
        • Or via optional digital inputs
    • User I/O: 
      • Disconnect and polarity-reversal relay control (only available with Ethernet option)
      • Digital 10-pin Molex type connector
  • Output:
    • Ripple and noise (voltage mode, typical):
      • Ripple and noise specified at full load, nominal AC input
      • Noise measured with 6 ft. cable, 1μf at load
    • Ripple (current mode):  <+/-0.04% of full scale rms current
    • Output voltage rise time (40-1000V):  ≈< 100 ms 10-90% of full scale typical - full resistive load 
    • DC current slew rate:  45A/ ms typical - resistive load 
    • Line regulation (with sense wires used):
      • (±10% of nominal AC input, constant load)
      • Voltage mode: +/- 0.01% of full scale (40-800V) 
      • Current mode: +/- 0.05% of full scale (40-800V) 
      • Voltage mode and current mode: +/- 0.05% of full scale (10-30V)
    • Load regulation (with sense wires used):
      • (no load to full load, nominal AC input)
      • Voltage mode: +/- 0.02% of full scale (40-800V) 
      • Current mode: +/- 0.1% of full scale 
    • Load transient response:  Recovers within 1 ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
    • Efficiency:  87% typical at nominal line and max load
    • Stability:  ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature, typical
    • Temperature coefficient:
      • 0.02%/ C of maimum output voltage rating for voltage set point, typical
      • 0.03%/ C of maimum output current rating for voltage set point, typical
    • Output float voltage:  Negative terminal within +/- 300 V of chassis potential

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

I just received the unit in my lab. This is better than Amazon!


-- Scot M.




Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

We received our purchase from Axiom and everything was expertly packed and the items are 100% complete and operational.  We’re definitely a satisfied customer.

John G.
Wernersville, PA




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com