Tektronix Encore

Transcat




Tektronix DPO7054
Oscilloscope, 500 MHz, 20 GS/s, 4 Ch.

Oscilloscopes >> More than 500 MHz, up to 1 GHz >> Oscilloscope, 500 MHz, 20 GS/s, 4 Ch.
Rent Used Test Equipment
Manufacturer: Tektronix
Model: DPO7054

Tektronix DPO7054 Oscilloscope, 500 MHz, 20 GS/s, 4 Ch.

Electronic Test and Measurement Equipment

Tektronix DPO7054 Oscilloscope, 500 MHz, 20 GS/s, 4 Ch. Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT TEKTRONIX DPO7054 Oscilloscope (call for availability)

The Tektonix DPO7054 Oscilloscope is a real-time digital phosphor oscilloscope and is the industry’s best solution to the challenging signal integrity issues faced by designers verifying, characterizing, debugging, and testing sophisticated electronic designs.

The Tektronix DPO7054 Oscilloscope features exceptional performance in signal acquisition and analysis, operational simplicity, and unmatched debugging tools to accelerate your day-to-day tasks. It has the largest screen in the industry and its intuitive user interface provides easy access to the maximum amount of information.

Features and Specifications of the Tektronix DPO7054 Oscilloscope include:

Features and Benefits:

  • 500 MHz Bandwidth Model for Serial and Digital Applications
  • Up to 40 GS/s Real-time Sample Rate on One Channel and up to 10 GS/s on All Four Channels
  • Up to 500 Megasamples Record Length with MultiView Zoom™ Feature for Quick Navigation
  • >250,000 wfms/s Maximum Waveform Capture Rate
  • Up to 310,000 Waveforms per Second with FastFrame™ Segmented Memory Acquisition Mode
  • User-selectable Bandwidth Limit Filters for Better Low-frequency Measurement Accuracy
  • MyScope® Custom Windows and Right Mouse Click Menus for Exceptional Efficiency
  • Event Search and Mark to Find Specific Events in the Entire Waveform
  • Pinpoint® Triggering provides the Most Flexible and Highest Performance Triggering, with Over 1400 Combinations to Address Virtually Any Triggering Situation.
  • 12.1” XGA Display with Touch Screen
  • Communications Mask Testing
  • Clock Recovery from Serial Data Streams
  • 64-bit NRZ Serial Pattern Trigger for Isolation of Pattern-dependent Effects up to 1.25 Gb/s
  • Low-speed Serial Protocol Triggering and Decode (I2C, SPI, RS-232, CAN, LIN, and FlexRay)
  • Technology-specific Software Solutions provide Built-in Domain Expertise for MIPI® D-PHY, Ethernet, USB 2.0 Compliance Testing, Jitter, Timing, Eye Diagram, Power, DDR Memory Bus Analysis, CAN, LIN, and FlexRay Network Design
  • OpenChoice® Software with Microsoft Windows XP OS enables Built-in Networking and Extended Analysis

Applications:

  • Signal Integrity, Jitter, and Timing Analysis
  • Verification, Debug, and Characterization of Sophisticated Designs
  • Debugging and Compliance Testing of Serial Data Streams for Telecom and Datacom Industry Standards
  • Low-speed Serial Bus Design (I2C, SPI, RS-232, CAN, LIN, and FlexRay)
  • Investigation of Transient Phenomena
  • Power Measurements and Analysis
  • Spectral Analysis

Characteristics:

  • Vertical System:
    • Input Channels:  4
    • Bandwidth (DSP Bandwidth Enhance): 500 MHz
    • Rise Time (DSP Bandwidth Enhance): 460 ps
    • Hardware Analog Bandwidth (-3 dB): 500 MHz
    • Rise Time 10% to 90% (Typical): 460 ps
    • Rise Time 20% to 80% (Typical): 310 ps
    • DC Gain Accuracy: ±1% with offset/position set to 0
    • Input Coupling: AC, DC, GND
    • Input Impedance (Software selectable):
      • 1 MO ±1% with 13 pF ±2 pF or
      • 50 O ±1%
    • Input Sensitivity: 
      • 1 MO: 1 mV/div to 10 V/div
      • 50 O: 1 mV/div to 1 V/div
    • Vertical Resolution: 8 bit (>11 bit with Hi Res)
    • Max Input Voltage:
      • 1 MO: ±150 V CAT I, derate at 20 dB/decade to 9 VRMS above 200 kHz
      • 50 O: 5 VRMS with peaks less than ±24 V
    • Position Range: ±5 divisions
    • Offset Range:
      • 1 mV/div to 50 mV/div: ±1 V
      • 50.5 mV/div to 99.5 mV/div: ±(1.5 V – 10 divisions)
      • 100 mV/div to 500 mV/div: ±10 V
      • 505 mV/div to 995 mV/div: ±(15 V – 10 divisions)
      • 1 V/div to 5 V/div: ±100
      • 5.05 V/div to 10 V/div: ±(150 V – 10 divisions)
    • Offset Accuracy:
      • 1 mV/div to 9.95 mV/div: ±0.2% (offset value-position) ±0.1 div ±1.5 mV
      • 10 mV/div to 99.5 mV/div: ±0.35% (offset value-position) ±0.1 div ±1.5 mV
      • 100 mV/div to 1 V/div: ±0.35% (offset value-position) ±0.1 div ±15 mV
      • 1.01 V/div to 10 V/div: ±0.25% (offset value-position) ±0.1 div ±150 mV
    • Delay Between Any Two Channels (Typical): =100 ps (50 O, DC coupling and equal V/div at or above 10 mV/div)
    • Channel-to-Channel Isolation (Any 2 channels at equal Vertical Scale Settings) (Typical):
      • =100:1 at =100 MHz
      • =30:1 between 100 MHz and 2.5 GHz
      • > 20:1 between 2.5 and 3.5 GHz
  • Time Base System:
    • Time Base Range: 50 ps/div to 1000 s/div
    • Time Resolution (in ET/IT mode): 500 fs
    • Time Base Delay Time Range: 5 ns to 250 s
    • Channel-to-Channel Deskew: Range ±75 ns
    • Delta Time Measurement Accuracy: ((0.06 / sample rate) + (2.5 ppm × Reading)) RMS
    • Trigger Jitter (RMS):
      • 1.5 psRMS (typical) with enhanced triggering OFF
    • Jitter Noise Floor:
    • Time Base Accuracy: ±2.5 ppm + Aging
  • Acquisition System:
    • Real-Time Sample Rates:
      • 1 Channel (Max): 20 GS/s
      • 2 Channels (Max): 10 GS/s
      • 3-4 Channels (Max): 5 GS/s
      • Equivalent Time Sample Rate (Max): 4 TS/s (for repetitive signals)
    • Maximum Record Length Per Channel:
      • Standard Configuration:
        • 1 Channel: 50 M
        • 2 Channel: 25 M 
        • 4 Channel: 12.5 M
      • Record Length Opt. 2RL:
        • 1 Channel: 125 M
        • 2 Channel: 50 M 
        • 4 Channel: 25 M
      • Record Length Opt. 5RL
        • 1 Channel: 250 M
        • 2 Channel: 125 M 
        • 4 Channel: 50 M
  • Maximum Duration at Highest Real-Time Resolution (1 Channel):
    • Resolution: 50 ps (20 GS/s)
    • Max Duration with Standard Record Length and Sample Rate: 2 ms
    • Max Duration with Opt 2RL: 4 ms
    • Max Duration with Opt 5RL: 10 ms

 

Other models in this series:

REQUEST A QUOTE




Testimonials

We received the unit here in Florida yesterday just before noon – less than 24-hrs from when we placed the order…Thank you for your exceptional and expedient service to minimize our down time and helping us bring this dire emergency to a happy, successful conclusion.


-- Timothy
Melbourne, FL



Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

Axiom Test has an excellent range of test equipment and is always super responsive to short notice requests. They are an extension of our quality and engineering team with the support they provide us. Thanks!

Eric G.
Phoenix, AZ




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600