Tektronix Encore

Transcat




Anritsu 37269B
Network Analyzer, 40 MHz - 40 GHz

Network Analyzers >> More than 20 GHz, up to 40 GHz >> Network Analyzer, 40 MHz - 40 GHz
Rent Used Test Equipment
Manufacturer: Anritsu
Model: 37269B

Anritsu 37269B Network Analyzer, 40 MHz - 40 GHz

Electronic Test and Measurement Equipment

Anritsu 37269B Network Analyzer, 40 MHz - 40 GHz Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

The Anritsu 37269B Vector Network Analyzer is a high performance analyzer designed to make fast and accurate S-parameter measurements of passive devices across the 40 MHz to 40 GHz frequency range. The Anristu 37269B network analyzer integrates a synthesized source, S-parameter test set and tuned receiver into a single compact package that is ideal for bench-top testing.

High throughput measurements are achieved in each model through the use of fast, 12-term error corrected sweeps, fast GPIB data transfers and an intuitive user interface. All measurement results are displayed on a large LCD color display or on an external VGA monitor.

Features of the Anritsu 37269B Network Analyzer include:

  • Fast Sweeping Synthesized Source
  • Auto Reversing Test Set
  • Solid-State Transfer Switch
  • Four Independent Displays
  • Four Channel Receiver
  • Internal Hard and Floppy Disk Drives
  • LRL/LRM Calibration
  • Adapter Removal Calibrations
  • Fast Measurement Throughput via GPIB

Dynamic Range:

Frequency

Max. Signal Into Port 2 (dBm)

Noise Floor (dBm)

Receiver Dyanamic Range (dB)

Port 1 Power (dBm, Typical)

System Dynamic Range (dB

0.04 

+20

-70

90

0

70

2

+3

-98

101

0

98

20

+3

-95

98

-5

90

40

+3

-93

96

-15

78

  • High Level Noise (typical):Measurement Throughput: Measurement times are based on a single 40 MHz to 20 GHz sweep with 10 kHz IF bandwidth (no averages) after a full 12-term calibration. Sweep times include retrace and band switch times.
  • Measurement Time (ms) vs. Data Points (typical):
    • Calibration Type/Data Points
      • 1 Port (3 Term): 3/60 51/250 101/330 401/960 1601/3300
      • Full 2 Port: 3/60 51/270 101/400 401/1000 1601/3600
  • Measurement Time vs. Sweep Mode for 101 Data Points (typical)
Sweep Mode Time (ms)   
Linear 350
List 350
CW 230
  • Measurement Time vs. IF BW for 101 Data Points (typical)
IF Bandwidth Time (ms)    
10 kHz 350
1 kHz 530
100 kHz 1900
10 Hz 14000
  • Measurement Time vs. Span for 101 Data Points (typical)
Frequency Span Time (ms)          
40 MHz to 40 GHz 500
20 GHz to 40 GHz 400
10 GHz to 11 GHz 250

Measurement Capabilities of the Anritsu 37269B include:

  • Number of Channels: Four independent measurement channels.
  • Parameters: S11, S21, S22, S12, or user defined combinations of a1, a2, b1, and b2. All measurements are made without the need to manually reverse the test device.
  • Measurement Frequency Range: Frequency range of measurement can be narrowed within the calibration range without recalibration. CW mode permits single frequency measurements, also without recalibration. In addition, the system accepts N discrete frequency points where 2 < N < 1601.
  • Domains: Frequency Domain, CW Draw, and optional High Speed Time (Distance) Domain.
  • Formats: Log Magnitude, Phase, Log Magnitude and Phase, Smith Chart (Impedance), Smith Chart (Admittance), Linear Polar, Log Polar, Group Delay, Linear Magnitude, Linear Magnitude and Phase, Real, Imaginary, Real and Imaginary, SWR, Power.
  • Data Points: 1601 maximum. Data points can be switched to a value of 801, 401, 201, 101 or 51 points without recalibration (if 1601 points were used in the calibration). In addition, the system accepts an arbitrary set of N discrete data points where: 2 < N < 1601. CW mode permits selection of a single data point without recalibration.
  • Reference Delay: Can be entered in time or in distance (when the dielectric constant is entered). Automatic reference delay feature adds the correct electrical length compensation at the push of a button. Software compensation for the electrical length difference between reference and test is always accurate and stable since measurement frequencies are always synthesized. In addition, The system compensates reference phase delay for dispersive transmission media, such as waveguide and microstrip.
  • Markers: Six independent markers can be used to read out measurement data. In delta-reference mode, any one marker can be selected as the reference for the other five. Markers can be directed automatically to the minimum or maximum of a data trace.
  • Enhanced Markers: Marker search for a level or bandwidth, displaying an active marker for each channel, and discrete or continous (interpolated) markers.
  • Marker Sweep: Sweeps upward in frequency between any two markers. Recalibration is not required during the marker sweep.
  • Limit Lines: Either single or segmented limit lines can be displayed. Two limit lines are available for each trace.
  • Single Limit Readouts: Interpolation algorithm determines the exact intersection frequencies of test data and limit lines.
  • Segmented Limits: A total of 20 segments (10 upper and 10 lower) can be generated per data trace. Complete segmented traces can be offset in both frequency and amplitude.
  • Test Limits: Both single and segmented limits can be used for PASS/FAIL testing. The active channel’s PASS or FAIL status is indicated on CRT after each sweep. In addition, PASS/FAIL status is output through the rear panel I/O connector as selectable TTL levels (PASS=0V, FAIL=+5V or PASS=+5V, FAIL=0V).
  • Tune Mode: Tune Mode optimizes sweep speed in tuning applications by updating forward S-parameters more frequently than reverse ones. This mode allows the user to select the ratio of forward sweeps to reverse sweeps after a full 12-term calibration. The ratio of forward sweeps to reverse sweeps can be set anywhere between 1:1 to 10,000:1.

 

Other models in this series:

REQUEST A QUOTE




Testimonials

It has been a pleasure doing business with Axiom.


-- Jim P.
New Mexico



Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

We received our purchase from Axiom and everything was expertly packed and the items are 100% complete and operational.  We’re definitely a satisfied customer.

John G.
Wernersville, PA




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600