YOKOGAWA 720210 ANALOG VOLTAGE INPUT MODULE (Call for Availability)

The Yokogawa 720210 is a high-speed, 12-bit, 2 channel, isolation, anolog voltage input module.

Specifications of the Yokogawa 720210 Analog Voltage Input Module include:

Specifications:

  • Effective measurement range:  Twice of setting range
  • Number of input channels:  2
  • Input coupling:
    • AC, DC, and GND
  • Maximum sample rate:  100 MS/s 
  • Input format:  Isolated unbalanced
  • Frequency characteristics (-3 dB point when sine wave of amplitude 60% of range is input):  DC to 20 MHz
  • Voltage-axis range setting:  50 mV to 200 V range (1-2-5 steps)
  • Maximum input voltage (at a frequency of 1 kHz or less):
    • Combined with the 700929 (10:1):  1000 V (DC + ACpeak)  CATll 
    • Direct input or cable not complying with the safety standard: 200 V (DC + ACpeak)
  • Maximum allowable common mode voltage (at a frequency of 1 kHz or less):
    • Working voltage of safety standard combine with the 700929 (10:1):  1000 Vrms (CATll) 
    • Direct input or cable not complying with the safety standard: 42 V (DC + ACpeak) (CAT l and CAT ll, 30 Vrms)
  • Vertical (voltage) axis accuracy (DC accuracy):  100mV to 200 V range:  ±(0.5% of range)
  • Input connector:  BNC connector (isolated type)
  • Input impedance:  1 MΩ ± 1%, approximately 35 pF
  • -3 dB point when AC coupled low frequency attenuation point:  10 Hz or less (1 Hz or less when using the 700929)
  • Common mode rejection ratio:  80 dB (50/60 Hz) or more (typical)
    • Temperature measurement:  120 dB or more (50/60 Hz, with 2-Hz filter ON, signal source resistance of 500 Ω or less) typical
  • Residual noise level (input section shorted):  ±1.1 mV or 1.5% of range whichever is greater (typical)
  • Withstand voltage:  1500 Vrms for 1 minute (across each terminal and earth) (60Hz)
  • Insulation resistance:  500 VDC, 10 MΩ or more (across each terminal and earth)
  • A/D conversion resolution:  12 bit (1500 LSB/range)
  • Temperature coefficient:  
    • Zero point:  100 mV to 200 V range:  ±(0.1% of range)/ C(typical)
    • Gain:  ±(0.05% of range)/ C(typical)
  • Bandwidth limit:
    • Select from OFF, 2 MHz, 1.28 MHz, 640 kHz, 320 kHz, 160 KHz, 80 kHz, 40 kHz, 20 kHz and 10 kHz
    • Cut-off characteristics:  -12 dB/OCT (when 2 MHz, typical)
  • Probe attenuation setting:
    • Voltage probe:  1:1, 10:1, 100:1, 1000:1
    • Current probe:  
      • 10 A:1 V for 700937/701933
      • 100 A:1 V for 701930/701931

Request A Quote

Rent      Buy      Repair
SUBMIT REQUEST
760-806-6600


Testimonial


  GET QUOTE  



Customers who viewed this also viewed


Astro Med Inc TMX-18 High Speed Data Acquisition Recorder, 18 Channel
Astro Med Inc TMX-18 High Speed Data Acquisition Recorder, 18 Channel





Home   |   Rental Equipment   |   Equipment Sales   |   Repair & Calibration   |   Sell Your Equipment   |   About Us   |   Contact   |   Get A Quote   |   Blog    



YouTube Facebook Google Plus Paypal
Get the latest deals first. Subscribe to our newsletter.    SUBSCRIBE


© 2020 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML     
© 2020 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
Phone: (760) 806-6600