The HP (Agilent) 70420A Phase Noise Test Set is the primary 4-slot component of the E5500 series Phase Noise Test System: E5501A, E5502A, E5503A, E5504A, E5501B, E5502B, E5503B, E5504B(predecessor of the Agilent N5500A phase noise test system). The frequency range of the 70420A is 50 kHz to 1.6 GHz (Option 201 extends the frequency from 1.2 GHz to 26.5 GHz - Not included).

Features and specifications of the HP 70420A include:

  • Low Frequency Input Range: 50 kHz to 1.6 GHz
  • High Frequency Input Range (w/ opt. 201): 1.2 GHz to 26 GHz
  • Low Frequency R Input Power: 0 dBm to +23 dBm
  • High Frequency R Input Power (w/ opt. 201): 0 dBm to +5 dBm
  • Low Frequency L Input Power: +15 dBm to +23 dBm
  • High Frequency L Input Power (w/ opt. 201): +7 dBm to +10 dBm
Offset Frequency         Detector Input Frequency
0.01 Hz to 20 kHz 50 kHz to 500 kHz
0.01 Hz to 200 kHz 500 kHz to 5 MHz
0.01 Hz to 2 MHz 5 MHz to 25 MHz
0.01 Hz to 20 MHz 25 MHz to 250 MHz
0.01 Hz to 100 MHz 250 MHz to 26.5 GHz
  • Noise Input Port:
    • Frequency: 0.01 Hz to 100 MHz
    • Amplitude: 1 volt peak max
    • Input impedance: 50 ohm (typical), (DC coupled, RL < 9.5 dB (typical))
  • Tuning Voltage Output:
    • Voltage Range: –12 volts, open circuit
    • Current: –20 mA, max
    • Output Impedance: 50 ohm, typical
  • Noise Floor Degradation:
    • Degrade system noise floor 1 dB for every dB reduction in R input levels less than: +15 dBm (Low frequency input)
  • Residual phase noise and spurious responses (does not include phase noise and spurious signals from a reference source):
    • Carrier frequency: 50 kHz to 1.6 GHz:
Offset Frequency System Noise Floor
      0.01 Hz       70 dBc/Hz
      1.0 Hz       130 dBc/Hz
      10 kHz       170 dBc/Hz
      >10 kHz       170 dBc/Hz
Offset Frequency Spurious Response
      .01 Hz       70 dBc
      0.1 Hz       100 dBc
      >10 Hz       112 dB
    • Carrier frequency: 1.2 GHz to 26.5 GHz (optional):
Offset Frequency  System Noise Floor
      0.01 Hz          55 dBc/Hz
      1.0 Hz       115 dBc/Hz
      32 kHz       160 dBc/Hz
      >32 kHz       160 dBc/Hz
Offset Frequency  Spurious Response
      0.01 Hz       50 dBc
      0.1 Hz       80 dBc
      >10 kHz       97 dBc

Request A Quote

Rent      Buy      Repair
SUBMIT REQUEST
760-806-6600


Testimonial







Home   |   Rental Equipment   |   Equipment Sales   |   Repair & Calibration   |   Sell Your Equipment   |   About Us   |   Contact   |   Get A Quote   |   Blog    



YouTube Facebook Google Plus Paypal
Get the latest deals first. Subscribe to our newsletter.    SUBSCRIBE


© 2020 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML     
© 2020 Axiom Test, All Rights Reserved
FAQ      Privacy      Terms      Site Map      Site Map XML

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
Phone: (760) 806-6600