Transcat

Tektronix Encore




Agilent N8242A, Keysight N8242A, HP N8242A
Arbitrary Waveform Generator SI Module, 10 Bit, 1.25 GS/s or 625 MS/s

Signal Generators >> Accessories and Other >> Arbitrary Waveform Generator SI Module, 10 Bit, 1.25 GS/s or 625 MS/s
Rent Used Test Equipment
Manufacturer: Keysight / Agilent / HP
Model: N8242A

Keysight / Agilent N8242A Arbitrary Waveform Generator SI Module, 10 Bit, 1.25 GS/s or 625 MS/s

Electronic Test and Measurement Equipment

Keysight / Agilent N8242A Arbitrary Waveform Generator SI Module, 10 Bit, 1.25 GS/s or 625 MS/s Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT KEYSIGHT N8242A (Agilent) ARBITRARY WAVEFORM GENERATOR SYNTHETIC INSTRUMENT (SI) MODULE (Call for Availability)

The Keysight N8242A Arbitrary Waveform Generator SI Module, with its high performance, flexibility, and high sampling rates, is the perfect tool for creating ideal waveforms for precise testing of radar, satellite, digital radio, and frequency agile systems.

Features and Specifications of the Keysight N8242A (Agilent) Arbitrary Waveform Generator SI Module include:

Features of the Keysight N8242A Module:

  • Dual channel, single ended and differential outputs with 500 and 250 MHz of instantaneous analog bandwidth per channel
  • Multiple module sychronization to simulate multi-emitter and multi-path scenarios
  • Complex waveforms can be created via advanced sequencing engine
  • Up to 125 k definable waveform segments
  • Up to 16 k unique definable sequences
  • Remote programming interface:  LAN over 100BASE-T LAN
  • IEEE 1588 time-based triggering
  • LXI hardware trigger bus
  • Full environmental specifications
  • LXI compliant

Specifications of the Keysight N8242A (Agilent) Arbitrary Waveform Generator SI Module:

  • Channels:
    • Two independent channels available as baseband or IF outputs
    • Channel 1:  Single-ended and differential
    • Channel 2:  Single-ended and differential
  • Modulation Bandwidth:
    • 1.25 GS/s sample rate (option 125)
    • 500 MHz per channel (1 GHz IQ bandwidth)
    • 625 MS/s sample rate (option 062)
    • 250 MHz per channel (500 MHz IQ bandwidth)
  • Resolution:  10 bits (1/1024 levels)
  • Output spectral purity (CH1 and CH2):  
    • 1.25 GS/s sample rate (option 125):
      • Harmonic distortion:  = -50 dBc for each channel DC to 500 MHz
      • Non-harmonic spurious:  = -75 dBc for each channel 1 kHz to 500 MHz
      • Noise floor:  = -150 dBc/Hz across the channel bandwidth
    • 625 MS/s sample rate (option 062):
      • Harmonic distortion:  = -50 dBc for each channel DC to 250 MHz
      • Non-harmonic spurious:  = -75 dBc for each channel 1 kHz to 250 MHz
    • Noise floor:  = -150 dBc/Hz across the channel bandwidth
  • Sample clock:
    • Internal:
      • Fixed 1.25 GS/s (option 125)
      • Fixed 625 MS/s (option 062)
    • Internal clock output:  +3 dBm nominal
    • External clock input:
      • Tunable 100 MS/s to 1.25 GS/s (option 125)
      • Tunable 100 MS/s to 625 MS/s (option 062)
    • External clock input drive level:  +5 to -15 dBm typical
    • Phase noise characteristics:
      • 1 kHz:  -95 dBc/Hz
      • 10 kHz:  -115 dBc/Hz
      • 100 kHz:  -138 dBc/Hz
      • 1 MHz:  -150 dBc/Hz
    • Noise floor:  -150 dBc/Hz
    • Accuracy:  Same as 10 MHz timebase input
  • Frequency reference input drive level:  +2 to +12 dBm into 50 Ω (+2 dBm nominal)
  • Waveform lengh:  8 MS per channel (16 MS with option 016)
    • Minimum waveform length:  128 samples
    • Waveform granularity:  8 samples
  • Segments:  1 to 32 k unique segments can be defined consisting of waveform start and stop address, repetitions and marker enable flags
  • Sequences:
    • A sequence is a contiguous series of waveform segments
    • Up to 32 k unique waveform sequences can be defined
  • Advanced sequencing:  Enables users to build and playback scenarios, which are comprised of one or more sequences
  • Analog output:
    • Output connector: SMA female
    • Output impedance:  50 Ω
    • Analog output levels specified into 50 Ω:
      • Passive mode:
        • Single-ended:  0.5 Vp-p
        • Differential:  N/A
      • Active mode:
        • Single-ended:  1 Vp-p with ±0.2 V offset
        • Differential:  N/A
      • Direct DAC mode:
        • Single-ended:  N/A
        • Differential:  1 Vp-p (0 volt offset)
    • Corrected passband flatness:  ±0.5 dB DC - 500 MHz (with 1.25 GHz clock)
    • Corrected passband group delay:  ±150 ps rms DC - 500 MHz (with 1.25 GHz clock)
    • Reconstruction filters:  500 MHz and 250 MHz realized as 7-pole Cauer Chebychev filters plus thru-line output
    • Pulse response:  Rise time (10 to 90%):  < ns Fall time (10 to 90%): < 1 ns Amplitude 0.5 V pk-pk
  • Power:  90 to 132 VAC, 50 to 60 Hz, or 195 to 267 VAC, 50 to 60 Hz (automatically selected), 90 watts maximum

REQUEST A QUOTE




Testimonials

For the first time in a long time, can I just say thanks for the excellent unit you sold me even better than the one in the picture. Fantastic to deal with a honest human for a change.


-- Walter R.




Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

We received the unit today. Thank you for this. Your team did an excellent job.

Bruce D.
Phoenix, AZ




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600