Manufacturer: Sorensen
Model: SGA600-50

Sorensen SGA600-50 DC Power Supply, 600V, 50A, 30kW

Electronic Test and Measurement Equipment

Sorensen SGA600-50 DC Power Supply, 600V, 50A, 30kW Product Datasheet Download Product Datasheet

Rent Test Equipment

Available Option Configurations

Config-01

  • E - Input Voltage 396 / 528VAC No charge
  • MSRP: $34,439 | In Stock!    GET QUOTE  

Product Overview

RENT Sorensen SGA600-50 (call for availability)

The Sorensen SGA600-50  is a Programmable Precision High Power DC Power Supply that provides front panel analog controls as well as essential features like 10-turn potentiometers for setting voltage and current, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.

Features of the Sorensen SGA600-50 include:

  • High Power Density: 30kW in a 6U chassis
  • Wide Voltage Range: 0-600V and 0-50 Amps
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise: Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection 
  • Display: 3½ digits
  • Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: Optional LXI Class C compliant communication through integrated web server
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only 

Specifications of the Sorensen SGA600-50 include:

Common:

  • Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line).
  • Parallel Operation: Up to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory.
  • Series Operation: Up to 2 units (see Output Float Voltage)

Input:

  • Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 - 242 VAC); 380/400 VAC (operating range 342 - 440 VAC); and 440/480 VAC (operating range 396 - 528 VAC)
  • Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings)
  • Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and  >0.69 typical at 440/480 VAC input
  • Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)

Environmental:

  • Operating Temperature: 0 to 50º C
  • Storage Temperature: -25º C to 65º C
  • Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C
  • Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
  • Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
  • Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant
  • Front Panel Dust Filter: 30 PPI (Pores Per Inch) - must ensure adequate airflow and / or derate max. temperature. 3U unit only.

Physical:

  • Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm)
  • Weight: 3U < 80 lbs. (36 kg) 6U

Output:

  • Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load
  • Ripple (Current Mode): <+/- 0.04% of full scale rms current
  • DC Voltage Slew Rate: 45A / ms typical - resistive load
  • Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Current Mode: +/- 0.05% of full scale
  • Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Current Mode: +/- 0.1% of full scale
  • Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
  • Efficiency: 87% typical at nominal line and max load
  • Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature
  • Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output current rating for current set point
  • Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/current.

Programming Specifications of the Sorensen SGA600-50 include:

Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: 3½ digits

Remote Analog Interface:

  • Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range
  • Current Accuracy: 0.8% of full scale

Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale

OVP:

  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale

User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)

Read-Back / Monitoring Specifications of the Sorensen SGA600-50 include:

Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: 3½ digits

Remote Analog Interface:

  • Accuracy: +/-1.0% of full scale (0 - 10V)

Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale

User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

We received the unit here in Florida yesterday just before noon – less than 24-hrs from when we placed the order…Thank you for your exceptional and expedient service to minimize our down time and helping us bring this dire emergency to a happy, successful conclusion.


-- Timothy
Melbourne, FL



Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

Axiom has been a huge help to our success in the high demand of Silicon Valley. We are pleased to continue to work with Axiom for our equipment needs.

Tony W.
Newark, CA




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600