Manufacturer: Sorensen
Model: SGA600-33

Sorensen SGA600-33 DC Power Supply, 600V, 33A, 20kW

Electronic Test and Measurement Equipment

Sorensen SGA600-33 DC Power Supply, 600V, 33A, 20kW Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT Sorensen SGA600-33 (call for availability)

The Sorensen SGA600-33  is a Programmable Precision High Power DC Power Supply that provides front panel analog controls as well as essential features like 10-turn potentiometers for setting voltage and current, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.

Features of the Sorensen SGA600-33 include:

  • High Power Density: 20kW in a 6U chassis
  • Wide Voltage Range: 0-600V and 0-33 Amps
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise: Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection 
  • Display: 3½ digits
  • Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: Optional LXI Class C compliant communication through integrated web server
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only 

Specifications of the Sorensen SGA600-33 include:

Common:

  • Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line).
  • Parallel Operation: Up to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory.
  • Series Operation: Up to 2 units (see Output Float Voltage)

Input:

  • Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 - 242 VAC); 380/400 VAC (operating range 342 - 440 VAC); and 440/480 VAC (operating range 396 - 528 VAC)
  • Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings)
  • Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and  >0.69 typical at 440/480 VAC input
  • Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)

Environmental:

  • Operating Temperature: 0 to 50º C
  • Storage Temperature: -25º C to 65º C
  • Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C
  • Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
  • Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
  • Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant
  • Front Panel Dust Filter: 30 PPI (Pores Per Inch) - must ensure adequate airflow and / or derate max. temperature. 3U unit only.

Physical:

  • Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm)
  • Weight: 3U < 80 lbs. (36 kg) 6U

Output:

  • Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load
  • Ripple (Current Mode): <+/- 0.04% of full scale rms current
  • DC Voltage Slew Rate: 45A / ms typical - resistive load
  • Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Current Mode: +/- 0.05% of full scale
  • Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Current Mode: +/- 0.1% of full scale
  • Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
  • Efficiency: 87% typical at nominal line and max load
  • Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature
  • Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output current rating for current set point
  • Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/current.

Programming Specifications of the Sorensen SGA600-33 include:

Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: 3½ digits

Remote Analog Interface:

  • Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range
  • Current Accuracy: 0.8% of full scale

Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale

OVP:

  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale

User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)

Read-Back / Monitoring Specifications of the Sorensen SGA600-33 include:

Front Panel Display:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: 3½ digits

Remote Analog Interface:

  • Accuracy: +/-1.0% of full scale (0 - 10V)

Remote Digital Interface:

  • Voltage Accuracy: +/- 0.1% of full scale
  • Current Accuracy: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale

User I/O:

  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

Great RF Test Equipment, in very good condition. I am very satisfied with the purchase and also with your management. It has been a pleasure to do business with you, and I hope to go on.


-- Jose




Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

Thank you for your quick response to our need.

Brenda S.
Loveland, CO




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600