Manufacturer: Keysight / Agilent / HP
Model: MSOX4024A

Keysight / Agilent MSOX4024A Oscilloscope, 200 MHz, 4 + 16 Chs.

Electronic Test and Measurement Equipment

Keysight / Agilent MSOX4024A Oscilloscope, 200 MHz, 4 + 16 Chs. Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT KEYSIGHT MSOX4024A (Agilent) OSCILLOSCOPE (Call for Availability)

The Keysight MSOX4024A is a four-channel model in the InfiniiVision 4000 X-Series, providing innovative touch triggering. It is surprisingly easy to use with its large, state-of-the-art capacitive touch screen. The MSOX4024A oscilloscope is fully upgradable, including bandwidth, and its unique 5-instruments-in-one design, provides superior performance, speed, and functionality.

Features and Specifications of the Keysight MSOX4024A(Agilent) Oscilloscope include:

Features of the Agilent MSOX4024A include:

  • One million waveforms per second update rate
  • MegaZoom IV smart memory technology
  • Standard segmented memory
  • Large 12.1-inch capacitive touch display
  • Interface designed for touch
  • Innovative InfiniiScan Zone touch triggering
  • 5 instruments in 1, with full upgradability, including bandwidth:
    • Oscilloscope  
    • Logic analyzer (MSO) 
    • Serial protocol analyzer, including USB (optional)
    • WaveGen 20 MHz dual channel arbitrary/function generator (optional)
    • Digital voltmeter (DVM) option:
      • with 3-digit voltage
      • with 5-digit frequency counter measurements

Specifications of the Keysight MSOX4024A (Agilent) include:

  • Bandwidth (-3 dB):  200 MHz
  • All-channel real-time bandwidth:  200 MHz
  • Calculated rise time (10 - 90%):  ≤ 1.75 ns
  • Input channels:  
    • 4 analog
    • 16 digital
  • Maximum sample rate:
    • 5 GSa/s half channel
    • 2.5 GSa/s all channel
  • Maximum memory depth:  Standard 4 Mpts, standard segmented memory
  • Display size and type:  12.1-inch high-definition capacitive touch display
  • Waveform update rate:  > 1 million waveforms per second
  • System bandwidth with N2894A standard passive probe: 200 MHz
  • Vertical system analog channels:
    • Hardware bandwidth limits:  Approximately 20 MHz (selectable)
    • Input coupling:  AC, DC
    • Input impedance:  Selectable:  
      • 1 MΩ ± 1% (16 pF)
      • 50 Ω ± 1.5%
    • Input sensitivity range:  1mV/div to 5 V/div (1 MΩ and 50 Ω)
    • Vertical resolution:  8 bits (measurement resolution is 12 bits with averaging)
    • Maximum input voltage:
      • 300 Vrms, 400 Vpk
      • Transient overvoltage 1.6 kVpk
      • With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
      • Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
    • DC vertical gain accuracy: ± 2.0% full scale
    • DC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting
    • Channel-to-channel isolation: ≥ 40 dB from DC to maximum specified bandwidth of each model
    • Offset range:
      • ± 5 V (< 10 mV/div)
      • ± 20 V (10 to 200 mV/div)
      • ± 75 V (> 200 mV/div)
  • Vertical system digital channels:
    • Digital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
    • Thresholds: Threshold per pod
    • Threshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
    • User-defined threshold range:  ± 8.0 V in 10 mV steps
    • Maximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk
    • Threshold accuracy:  ± (100 mV + 3% of threshold setting)
    • Maximum input dynamic range:  ± 10 V about threshold
    • Minimum voltage swing:  500 mVpp
    • Input impedance:  100 kΩ ± 2% at probe tip
    • Input capacitance:  ~8 pF
    • Vertical resolution: 1 bit
  • Horizontal system analog channels:  
    • Time base range:  2 ns/div to 50 s/div
    • Time base accuracy:  ± 10 ppm
    • Time base delay time range:
      • Pre-trigger:  Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
      • Post-trigger: 1 s to 500 s
    • Channel-to-channel deskew range:  ± 100 ns
    • Δ Time accuracy (using cursors):  ± 0.001% of reading ± 0.16% screen width ± 30pS
    • Modes:  Main, zoom, roll, XY
    • XY:
      • On channels 1 and 2 only
      • Z Blanking on ext trigger input, 1.4 V threshold  
      • Bandwidth:  Maximum bandwidth
      • Phase error at 1 MHz: < 0.5 degree
      • Time base: 200 ns/div to 50 ms/div
  • Horizontal system digital channels:  
    • Minimum detectable pulse width:  2 ns
    • Channel-to-channel skew:
      • 2 ns (typical)
      • 3 ns (maximum)
  • Aquisition system:
    • Maximum analog channels sample rate:  
      • 5 GSa/s half channel interleaved
      • 2.5 GSa/s all channel
    • Maximum analog channels record length:
      • 4 Mpts half channel interleaved
      • 2 Mpts all channel
    • Maximum digital channels sample rate:  1.25 GSa/s
    • Maximum digital channels record length:  2 Mpts (with digital channels only)
    • Modes:
      • Normal:  Default mode
      • Peak detect:  Capture glitches as narrow as 200 ps at all time base settings
      • Averaging:  Selectable from 2, 4, 8, 16, 64, ... to 65,536
      • High resolution:
        • Real time boxcar averaging reduces random noise and effectively increases vertical resolution
        • 12 bits:  ≥ 50 μs/div
        • 11 bits:  ≥ 20 μs/div
        • 10 bits:  ≥ 10 μs/div
        • 9 bits:  ≥ 5 μs/div
      • Segmented:
        • Segmented memory optimizes available memory for data streams that have long dead times between activity
        • Maximum segments = 1000
        • Re-arm time = 1 μs (minimum time between trigger events)
        • Re-arm time when use with the InfiniiScan Zone = 65 us or faster (typical)
      • Roll:  
        • Displays the waveform moving across the screen from right to left
        • Available at the time base 50 ms/div or slower
  • Trigger system:
    • Trigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
    • Trigger modes:
      • Normal: Requires trigger event for scope to trigger
      • Auto : Triggers automatically in absence of trigger event
      • Single:
        • Front panel button that triggers only once on a trigger event
        • Press [Single] button again for scope to find another trigger event, or press [Run] front-panel button to trigger continuously in either Auto or Normal mode
      • Force:  Front panel button that forces a trigger
    • Trigger coupling:  
      • DC: DC coupled trigger
      • AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); < 50 Hz (external)
      • High frequency reject:  Cutoff frequency ~ 50 kHz
      • Low frequency reject:  Cutoff frequency ~ 50 kHz 
      • Noise reject:
        • Adds hysteresis to the trigger circuitry
        • Selectable OFF or ON
        • Decreases sensitivity 2x
    • Trigger holdoff range: 40 ns to 10.00 s  
    • Trigger sensitivity:
      • Internal:
        • < 10 mV/div: greater of 1 div or 5 mV
        • ≥ 10 mV/div: 0.6 div
      • External:
        • ± 1.6 V:  
          • 40 mVpp DC to 100 MHz
          • 70 mVpp 100 MHz to 200 MHz
        • ± 8 V:  
          • 200 mVpp DC to 100 MHz
          • 350 mVpp 100 MHz to 200 MHz
    • Trigger level range:
      • Any channel:  ± 6 div from center screen
      • External:  
        • ± 8 V range = ± 8 V
        • ± 1.6 V range = ± 1.6 V
  • Connectivity:
    • USB 2.0 hi-speed host port:
      • x3 ports, 2 front and one rear panel
      • Supports memory devices, printers, keybords and mice
    • USB 2.0 hi-speed device port:
      • One port on rear panel
      • USB Test & Measurement Class (USBTMC) compatible
    • LAN port:
      • 10/100Base-T port on rear panel
      • LXI IPv6 extended function
    • Web remote control:  VNC Web interface (via major Web browsers)
    • Video out port:  
      • SVGA out on rear panel
      • Connect oscilloscope display to an external monitor or projector
    • GPIB port:  N4865A GPIB-to-LAN adapter (optional)
    • 10 MHz out/in:  
      • BNC connector on the rear panel
      • Suported modes:  Off, 10 MHz out, or reference signal mode (10 MHz in)
    • Trigger out:  
      • BNC connecter on the rear panel 
      • Supported modes:  triggers, mask, waveform generator 1 sync pulse, and waverform generator 2 sync pulse

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

Axiom has been a huge help to our success in the high demand of Silicon Valley. We are pleased to continue to work with Axiom for our equipment needs.


-- Tony W.
Newark, CA



Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

We received the unit today. Thank you for this. Your team did an excellent job.

Bruce D.
Phoenix, AZ




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600