California Instruments 5001iX Series II AC and DC Source and Power Analyzer, Single Phase
California Instruments 5001iX Series II AC and DC Source and Power Analyzer, Single Phase California Instruments 5001iX, AC Power Supply, Power Analyzer, rent, rental, used, refurbished  


California Instruments 5001iX Series II AC and DC Source and Power Analyzer, Single Phase  

The California Instruments 5001iX is a combination of AC Source, DC Source and Power Analyzer and is designed for use in a wide variety of applications. The 5001iX provides high load current capability, multi or single phase output modes and built-in power analyzer measurements. Additional features like line distortion simulation (LDS), arbitrary waveform generation and programmable output impedance address requirements for product quality and regulatory compliance.

The built-in output transient generation and readback measurement capability offers the convenience of an easy to use and integrated test system, allowing manufacturers of electronic equipment to evaluate and test their products over a wide range of input conditions.

The California Instruments 5001iX, with an output frequency range up to 500 Hz, is well suited for aerospace applications. Precise frequency control and accurate load regulation are key requirements in these applications. The standard IEEE-488 control interface and SCPI command language provide for easy integration into existing ATE systems.

The 5001iX is designed to meet AC source requirements for use in Euronorm EN 61000 compliance testing. For flicker testing, the programmable output impedance capability of the 5001iX can be used to create the required IEC 725 reference impedance.

With a crest factor of up to 5:1, the 5001iX AC source can drive difficult nonlinear loads with ease. Since many modern products use switching power supplies, they have a tendency to pull high repetitive peak currents. The 5001iX can deliver up to 110 Amps of repetitive peak current (low range) to handle such loads.

Windows application software is included and provides easy access to the units capabilities, including:

  • Steady state output control (all parameters)
  • Create, run, save, reload and print transient programs
  • Generate and save harmonic waveforms
  • Generate and save arbitrary waveforms
  • Download data from a digital storage oscilloscope
  • Measure and log standard measurements
  • Capture and display output voltage and current waveforms
  • Measure, display, print and log harmonic voltage and current measurements
  • Run IEC61000-4-11, IEC61000-4-14 and IEC61000- 4-28 test programs
  • Display IEEE-488 or RS232C bus traffic to and from the AC Source to help you develop your own test

Other features, functions of the 5001iX include:

  • Harmonic Waveform Generation: Define harmonic waveforms by specifying amplitude and phase for up to 50 harmonics. Up to 200 waveforms can be stored and given a user defined name for easy recall.
  • Arbitrary Waveform Generation: Provides an alternative method of specifying AC anomalies by providing specific waveform data points. The GUI program provides a catalog of custom waveforms and also allows real-world waveforms captured on a digital oscilloscope to be downloaded to one of the many AC source’s waveform memories. Simulates the effect of real-world AC power line conditions on a unit under test in both engineering and production environments.
  • AC and DC Transient Generation: Allows complex sequences of voltage, frequency and waveshapes to be generated. This further enhances the 5001iX's capability to simulate AC line conditions or DC disturbances. When combined with the multi phase arbitrary waveform capabilities, the AC and DC output possibilities are truly exceptional.
  • Measurement and Analysis: Built-in data acquisition system that continuously monitors all AC source and load parameters.
    • Conventional Measurements such as Common AC and DC measurement parameters are automatically provided and displayed in numeric form on the front panel LCD display. The following measurements are available: Frequency, Vrms, Irms,, Ipk, Crest Factor, Real Power (Watts), Apparent Power (VA) and Power Factor.
    • Harmonic Analysis: Provides detailed amplitude and phase information on up to 50 harmonics of the fundamental voltage and current for either one or three phases. Harmonic content can be displayed in both tabular and graphical formats on the front panel LCD for immediate feedback to the operator. Alternatively, the included GUI program can be used to display, print and save harmonic measurement data. Total harmonic distortion of both voltage and current is calculated from the harmonic data.
    • Waveform Acquisition: Based on real-time digitization of the voltage and current waveforms using a 4K deep sample buffer. This time domain information provides detailed information on both voltage and current waveshapes. Waveform acquisitions can be triggered at a specific phase angle or from a transient program to allow precise positioning of the captured waveform with respect to the AC source output.

Specifications of the Califorina Instruments 5001iX:

  • Operating Modes: AC, DC or AC+DC
  • AC Mode Output:
    • Range: 16 - 500 Hz
    • Resolution: 0.01 Hz < 81.91 Hz  /  0.1 Hz > 82.0 Hz
  • Power (max AC power per phase at full scale): 5000 VA
  • Load Power Factor: 0 to unity at full ouput VA
  • AC Voltage:
    • Voltage Range Pairs (Low/High):
      • 0-135V / 0-270V
      • 0-150V / 0-300V
  • Load Regulation:
    • In High Voltage Range:
      • < 0.5% DC to 100 Hz
      • < 0.6% 100 Hz to 500 Hz
    • In Low Voltage Range:
      • < 2.2% 100 Hz to 500 Hz
  • Line Regulation: < 0.1% for 10 % line change
  • Output Noise (20 kHz to 1 MHz):
    • < 250 mVrms typ.
    • < 500 mVrms max.
  • Harmonic Distortion:
    • Less than 1% from 16 - 66 Hz
    • Less than 2% at 400 Hz (into linear load)
  • DC Offset: < 20 mV
  • External Amplitude Modulation:
    • Depth: 0 - 10 %
    • Frequency: DC - 2 KHz
  • Isolation Voltage: 300 VRMS output to chassis
  • Peak Repetitive AC Current:
    • High Range: 96
    • Low Range: 110
  • Steady State AC Current:
    • 270V Range: 18.5
    • 135V Range: 37.0
    • 300V Range: 16.7
    • 150V Range: 33.3
  • Programming Accuracy
    • Voltage (rms): ± 0.5 % of range, 16 to 400 Hz
    • Frequency: ± 0.01 % of programmed value.
    • Current Limit: - 0 % to + 7 % of programmed value + 0.5 A.
    • Phase: < 1.5° with balanced load @ 50/60 Hz.
  • Programming Resolution
    • Voltage (rms): 100 mV
    • Frequency: 0.01 Hz from 16 - 81.91 Hz / 0.1 Hz from 82.0 - 500.0 Hz
    • Current Limit: 0.1 A for single units / 1.0 A for paralleled units. Phase: 0.1°
    • Output Relay: Push button controlled or bus controlled output relay
    • Output impedance: Programmable Z for 50 Hz fundamental.
    • Resistive:
      • range 17 - 1000 mOhm
      • resolution 4 mOhm
      • accuracy 2 % FS
    • Inductive:
      • range 230 - 1000 μH
      • resolution 4 μH
      • accuracy 2 % FS

 Measurements - Standard

Parameter
Range
Accuracy (+/-)
Accuracy (+/-)
Resolution
AC Measurements




Frequency
16-500 Hz
0.01% + 0.01 Hz
0.01% + 0.01 Hz
0.01 Hz


< 100 Hz
100-500 Hz

RMS Voltage
0-300 V
0.05V + 0.02%
0.1V + 0.02%
10 mV
RMS Current
0-40 A
0.05 A + 0.02%
0.1 A + 0.02%
1 mA
Peak Current
0-120 A
0.05 A + 0.02%
0.1 A + 0.02%
1 mA

Crest Factor

0.00-6.00
0.05

0.05


0.01
Real Power 0-6 kW
10 W + 0.1%
20 W + 0.1%
1 W
Apparent Power 0-6 kVA
10 VA + 0.1%
20 VA + 0.1%
1 VA
Power Factor
0.00-1.00
0.01 0.02 0.01
DC Measurements





DC Voltage
0-300 V
150 mV

10 mV
DC Current
0-40 A
70 mA
1 mA
Power
0-6 kW
15 W
1 W

  • DC Mode Output (max DC power at full scale of DC voltage range: 3500W
  • Votage Ranges (selectable combinations):
    • High = 0-270 V  Low = 0-135 V
    • High = 0-300 V  Low = 0-150 V
  • Load Regulation: see AC mode
  • Line Regulation: see AC mode
  • Output Noise: < 250 mVrms typ. < 500 mVrms max. (20 kHz to 1 MHz)
  • Max. DC Current Capability (Maximum DC current in lowest DC range pair):
    • 270V: 13
    • 135V: 26

Parameter Range Accuracy (+/-) Resolution
Frequency Fundamental Harmonics

16.00-500.0 Hz

32.00 Hz - 19.5 kHz

0.01% + 0.01 Hz

.01 Hz

.01 Hz

Phase 0.0 - 360.0° 2° typ. 0.5°
Voltage Fundamental Harmonics 2 - 50

250 mV

0.1% + 250 mV+0.1% /1 kHz

10 mV

10 mV

Current Fundamental Harmonics 2 - 50

50 mA

0.1% + 50 mA +0.1% /1 kHz

10 mA

10 mA

  • Current Limit: Programmable from 0 A to max. current for selected range.
  • AC+DC Mode Output Power: Full AC power if DC component is less than 20 % of full scale voltage. Full DC power if DC component is above 20 %.
  • System
    • Non Volatile Memory storage:
      • 8 instrument setups
      • 200 user defined waveforms
    • Waveforms
    • Waveform Types: Sine, Square, Clipped sine, User defined
    • User defined waveform storage: Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200. One group can be active at a time.
    • Transient Programming
    • Transient Types:
      • Voltage: drop, step, sag, surge, sweep
      • Frequency: step, sag, surge, sweep
      • Voltage and Frequency: step, sweep
    • Transient List Parameters: Voltage, Frequency, Time or Cycles, Slew rate, Waveform shape, Phase angle, Repeat
    • Transient lists storage: up to 32 transient steps per list
  • Time resolution / range: 1 ms / 1 ms - 90000 s
  • Maximum slew rate: 200 μs for 10% to 90% of full scale change into resistive load
  • Waveform Acquisition Channels: Voltage and Current for each phase.
  • Memory Depth: 4096 samples/channel.
  • Maximum Sample Rate: 39.0625 ks/s. Programmble from 39 ks/s to 3.9 ks/s over the bus.
  • Triggering: Auto, Phase, Transient.
  • Trigger Delay:
    • Pre-trigger
      • 0 - 104 ms 1ø
      • 0 - 312 ms 3ø
    • Post-trigger
      • 0 - 1000 msec. (at max. sample rates)
  • Display: Front panel Graphics Display with cursors.
  • Bus Interface: Full bus access to waveform acquisition system.
  • Remote Control
    • IEEE-488 Interface: IEEE-488 (GPIB) talker listener.
    • Subset:
      • AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6 IEEE-488.2 SCPI Syntax
    • RS232C Interface:
      •  9 pin D-shell connector
      • Handshake: CTS, RTS
      • Data bits: 7,8
      • Stop bits: 1,2
      • Baud rate: 9600, 19200, 38400
      • IEEE-488.2 SCPI Syntax
      • Supplied with RS232C cable
    • System Interface
      • Inputs:
        • Remote shutdown
        • External Sync
        • Clock/Lock (option)
      • Outputs:
        • Function Strobe
        • Clock/Lock (option)
  • AC Input:
    • Voltage:
      • Standard: 208-240 ± 10% VAC (L-L, 3ø)
      • Option 400: 400-480 ± 10% VAC (L-L, 3ø)
    • Current: Input Line Current (per phase):
      • 187-264V: 23A
      • 360-528V: 12A
  • Inrush Current per chassis:
    • < 100 Apk for 100 μs at 208-240 V
    • < 50 Apk for 100 μs at 400-480 V
  • Frequency: 50-60 Hz ± 10 %
  • Efficiency: 75 % typical
  • Power Factor: 0.6 typical
  • Hold-up Time: At least 10 ms
  • Protection
    • Over Load: Constant Current or Constant Voltage mode
    • Over Temperature: Automatic shutdown
    • Regulatory: IEC1010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
    • RFI Suppression: CISPR 11, Group1 , Class A
 

MSRP: $15,045.00

Our Price: $Call For Price


 

Interested in renting a California Instruments 5001iX Series II AC and DC Source and Power Analyzer, Single Phase? Axiom rents test equipment. Call (760) 806-6600 for more test equipment rental information or email sales@axiomtest.com. Interested in renting a California Instruments 5001iX Series II AC and DC Source and Power Analyzer, Single Phase ? Call (760) 806-6600 for more test equipment rental information or email sales@axiomtest.com.

 